1 EN-898X USER MANUAL 1. Introduction…………………………………………….2 2. Specification………………..…………………………..6 3. Setup 3-1. Installing the server board………………………….7
10 Notice The white screw is used to support the motherboard. M/B Insulation PAD: The M/B Insulation PAD above the pedestal will be used
11 as follows: aim at the holes holes Affix the tape to the pedestal.
12 Cabling the Server Board After mounting the server board, it needs to be cabled to the following chassis the Floppy drive the disk drive ass
13 3.4 Installing Optional Peripherals and Devices Hard Drives Your server does not include hard drives. You must purchase them separately and instal
14 3. 8981: Reinstall HDD into the chassis 8982/8983: Reinstall HDD into the chassis, and make sure that the lever is at parallel angle to th
15 If you will fix the 1.6’' HDD at the second tray, then installing the shield consists of the following steps: 1. Hook the shield with the HDD
16 CD-ROM/Floppy(8981/8982) Installing CD-ROM/FDD: 1. Remove the screws that used to fix the CD-ROM shield. 2. Remove the CD-ROM shield from the
17 Power Supply Boxed dimension is 330.2x106x82.2mm (W*D*H) To fix power supply: 1. Slide the power supply into the chassis and make sure it is sea
18 Cooling Fans Cooling fans(8981) 1. Insert the fan assembly into the chassis. 2. Plug the fan cables back into the connectors on the power. Back p
19 Rear side cooling fans(8982/8983) Installing the Cooling fans consists of the following steps: 1.Fix the I/O shields. 2.Nip the left
2 Introduction The EN-898X 2U Rackmount Chassis is a brand new product from Enlight Corporation. It provides the perfect solution for users who need
20 as follows: L1/R1: the left fan L2/R2: the second fan L3/R3: the right fan
21 Notes: If installing the Enlight’s I/O shield, make sure that the three hooks is at 80 angle to the chassis, then fix the three fans.
22 PCI Slot 898X C01 You can add three PCI cards to this server. Installing PCI SCSI add-in card: Insert the riser card to the PCI slot. Insert the
23 898X D01 You can add Low-profile PCI cards to this server.
24 898X E01 You can add two PCI cards to this server.
25 3.5 Installing 898X in the cabinet Screw the inner rails to both sides of the chassis. Position the bracket in the cabinet and screw the outer rai
26 3. ID Select(2 ID group) S1 off 0-5 S1 on 8-13 4. The Back Plane LED SAF-TE control the red LED will be blinking HDD the green LED will b
27 Note: Issuing a SCSI reset message or SCSI bus device reset message does not change the state of the indicator lights. 3HDD Back Plane 1. SCSI
28 3 4 ID OPEN OPEN 0,1,2 SHORT OPEN 3,4,5 OPEN SHORT 8,9,10
29 The identify LED can be flashed with or without a drive inserted in the slot. Consequently, the identify LED indicates which slot is housing the f
3 8981
30 7.About the LED panel and front panel 1. LED panel Power LED: When system turn on, the LED will be access.(green) Fan Fail LED: When the Fan er
31 TEMP Alarm LED: When the chassis’s temperature over Safe temperature, the LED will be show in and annunciator will start. NIC Activity LED: When
32 NMI Switch: Puts server in a halt state for diagnostic purposes. The button is recessed and allows you to issue a nonmaskable interrupt. After i
33 9. About SAF-TE(8982/8983) SAF-TE is proposed and standardized by Conner and Intel. It can work properly under standard SCSI adaptor and RAID cont
34 10.SCSI MANAGER(8982/8983) Usage of SCSI Manager For the first time the SCSI Manager is being used, it will require a serial number to be entered
35 When click on any of the options on the left panel, the information of the related topic will be displayed on the right panel, the settings wit
36 Users can modify every digit that was written onto the files that contain the settings, under the Common user mode, some general information would
37 example: IDE port 0, AIC78U21, etc. When click on their right panel, the interface control card’s processing. Ability parameter will be displ
38 status: Enclosure Configuration Enclosure Status Device Status Global Status When click on the Enclosure Configuration, the right panel will dis
39 When click on the Global Flags, the right panel will display some information Audible Alarm Control Flag Global Failure Indication Global Warn
40 SAF-TE COMMAND: 1.Read Enclosure Configuration 2.Read Enclosure Status 3.Read Device Slot Status 4.Read Global Flags 5.Write Device Slot Status 6
41 Send Command:Send the current command, when writing the command, please assign the contents in the buffer zone and byte, but command code is not i
42 Auto-update and Manual-update Configuration: Show as the following menu: If the AutoUpdate item is selected, the program will be updated automa
43 Note 1. First set up this compress package (SCSI manager), then load in the 8721,8982 or 8983 device and those devices could be automatically inst
44 4. We can update the software if we need to set up new equipment.
45 11. Addenda 898X series compare HDD External drive PCI Slot Fan 8981C01 3PCI(Provide 32bits PCI Riser card /option 64 bits PCI Riser card) 89
5 8983 notice: this pictures are just for reference.
6 Specifications EN-898X Rackmount Chassis Specifications Mainboard for factor follow SSI & ATX 12” x 13” specification Power Supply follow SSI
7 Setup WARNING The power button on the front panel DOES NOT turn off the AC power. To remove power from server, you must unplug the AC power cord(s)
8 PIC 3.1 Mounting the Server Board With the cover off, you can now mount the server board in the chassis. Before you begin, make sure you have
9 5 Align the board by making sure the standoffs with shoulders are inserted into their matching holes on the board. 6 Mount the board to the chass
Comments to this Manuals